TDS Mini Controller (0.0 to 49.9 ppm) - BL983324

The BL983324 is a compact, panel mounted, process controller for measuring total dissolved solids (TDS) of a process stream that is within the 0.0 to 49.9 ppm (mg/L) range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to supply power to a dosing pump or a solenoid connected to a valve. The BL983324 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation.

*The BL983324 uses a 0.5 conversion factor in which 1.0 µS/cm = 0.5 ppm.

Multicolor LED Indicator

LED changes color based on status.

Fire Retardant Casing

For additional safety the controllers outer case is made of fire resistant plastic.

Splash Resistant Cover

A clear plastic cover protects the face panel from dirt and liquids.

Mediray is Hanna Instruments’ authorised distributor in New Zealand. To purchase our products, please see the details below.

BL983324

Adjustable Dry Contact Dosing Relay

The BL983324 features a dosing relay that is activated when the reading is above a user programmable set point.

Programmable Overdose Protection

For enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.

Relay Control Override

With the flick of a switch the mini controller’s relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.

Multicolor LED Indicator

Multicolor LED indicator allows an operator to quickly check the status of the controller.

  • Green = Meter in measurement mode and reading is below the set point.
  • Orange/Yellow = Reading is above the set point and the relay is activated.
  • Blinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.
BL983324

Fuse Protected Dosing Contacts

The relay dosing contact is rated for up to a 2A load and is fuse protected.

Labeled Termination Connections

Quick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.

HI7634

1/2″ NPT Male Threaded Amperometric Probe for Mounting In-line*

The BL983324 mini controller uses the HI7634 conductivity probe that is available with different cable lengths.

*HI7634 is not included and must be ordered separately

Specifications

SKU BL983324
Name TDS Mini Controller (0.0 to 49.9 ppm) – BL983324
TDS Range 0.0 to 49.9 ppm (mg/L)
TDS Resolution 0.1 mg/L ppm (mg/L)
TDS Accuracy ±2% f.s.
TDS Calibration manual, with CAL trimmer
EC/TDS Temperature Compensation automatic from 5 to 50°C (41 to 122°F) with β =2%/oC
EC to TDS Conversion Factor 0.5
EC/TDS Dosing Relay maximum 2A (fuse protected), 250 Vac, 30 VDC
Over Dosing Control adjustable, typically from 5 to approximately 30 minutes
Power Supply models “-0”: 12 VDC adapter (included)
models “-1”: 115/230 VAC; 50/60Hz
Dimensions 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)
Weight models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)

Manuals

Ordering info

BL983324-1 (115/230 VAC) and BL983324-0 (12 VDC) are supplied with mounting brackets, transparent cover and instruction manual.

Additional information

Weight 0.45 kg
Parameter

Conductivity/TDS

TDS Accuracy

±2% f.s.

TDS Calibration

manual, with CAL trimmer

TDS Range

0.0 to 49.9 ppm (mg/L)

TDS Resolution

0.1 mg/L ppm (mg/L)

Where to buy

Mediray is Hanna Instruments’ authorised distributor in New Zealand. To purchase our products, please see the details below.

Phone: 0800 633 472

[email protected]

www.mediray.co.nz